Home > Products > Salt Spray Tester > JK-C series >JK-60C,600*450*400 with automatic timing function
Products

JK-60C,600*450*400 with automatic timing function

Spray method: Adopting bernoute principle to absorb brine and then atomize, the degree of atomization is even, no blocking phenomenon of crystallization, can ensure the standard of continuous test. Nozzles: made of special glass nozzles, the size of the spray can be adjusted. Spray flow rate adjustment 1-2m1 (m1/8ocm'/nh) (16-hour average) Spray mode: continuous type Adopt the direct heating method, the heating speed is fast to reduce the standby time, when the temperature reaches ON. OFF switching, accurate temperature, less power consumption.(heating tube is made of high corrosion resistance heating system: titanium tube).

1. Product parameter:

Voltage: 110V
Power: 2000W
Laboratory volume: 110L
Inner size: 23.6*17.7*15.7 inch (600*450*400mm)
Outer size: 40.5*22.4*38.5 inch (1030*570*980mm)
Spray method: continuous

 

2. Product display:



3. Product information:

 

-----All equipment needed in the  test: Spray nozzle, salt water barrel, test piece support, spray liquid  collection container, test chamber, salt water, supply tank, pressure tank,  supply equipment and exhaust equipment required for compressed air, the device  is shown in Fig, and test as followed.
-----Blunt material is required, it is required that the material itself cannot  be corroded, and it can not affect the corrosion test.
-----The fog nozzle cannot spray the test liquid directly to the sample , the  solution at the top of the spraying chamber cannot drop on the test piece.
-----The test liquid dropped from test piece cannot flow back to the salt bucket  again for the test.
-----The solution should not contain grease and dust, so you have to prepare an  air cleaner.
-----The level area of the spray taking device is 80 cm2, the diameter is about  10 cm. Put the spray taking device beside the test piece.
-----Spray liquid should be collected at least 16 hours, an average per hour can  be collected 2ml to 1ml solution. Use the final average to represent the amount  of spray.
-----The concentration of the Sodium Chloride Solution should be maintained at  40~60g/L.
-----The temperature of the pressure barrel should be kept in 47+1 degree,  temperature of the brine barrel should be kept in 35+1 degree.

-----The machine have timing  function, and you could set time to open or close automatically.

 

4. Product dimensions:



5. Spray method:

 

-----Adopting bernoute principle  to absorb brine and then atomize, the degree of atomization is even, no blocking  phenomenon of crystallization, can ensure the standard of continuous test.
-----Nozzles: made of special glass nozzles, the size of the spray can be  adjusted.
-----Spray flow rate adjustment 1-2m1 (m1/8ocm'/nh) (16-hour average)
-----Spray mode: continuous type
-----Adopt the direct heating method, the heating speed is fast to reduce the  standby time, when the temperature reaches ON. OFF switching, accurate  temperature, less power consumption.(heating tube is made of high corrosion  resistance heating system: titanium tube).